Atomic Absorption Spectroscopy

TRACE Atomic Absorption Spectrometers



Atomic Absorption Spectrometer Atomic Absorption Spectrometer

TRACE AI1200

TRACE 1300

The TRACE Atomic Absorption Spectrometer (AAS) is an ideal solution for a wide range of elemental analysis applications. Equipped with refined optics, cutting-edge graphite furnace technology, a solid PTFE spray chamber and the most advanced, all-in-one autosampler on the market, the TRACE is the perfect solution for both labs and industrial settings alike.

The TRACE Series is customizable with various combinations of flame, graphite furnace and vapor/hydride generator atomizers to meet the user’s specific needs. The instrument is uniquely designed for a quick, motorized transition between flame, graphite furnace and vapor/hydride generator atomizers - perfect for the analysis of a wide range of elements with minimal downtime. Furthermore, features like an auto-aligned six-lamp turret, online dilution and Fast Dry technology minimize intervention and provide rapid testing of samples.

Atomic absorption spectroscopy is common not only in traditional laboratory settings but also in hospitals and industrial settings, including serum, metallurgical, fertilizer, petrochemical, wastewater and paint testing. Undoubtedly, TRACE Atomic Absorption Spectrometers have been created with the user in mind. The AISPEC software allows users to quickly and easily develop their own unique methods or select from the software’s saved templates based on conventional procedures.


TRACE Configurations

TRACE AI1200

The TRACE AI1200 is Aurora’s most popular atomic absorption spectrometer which combines advanced features with excellent quality.

Atomizer combinations include:
Flame | Flame/Graphite Furnace | Flame/Vapor-Hydride Generator | Flame/Graphite Furnace/Vapor-Hydride Generator. Aurora’s advanced autosampler is available on all these configurations

TRACE 1300

The TRACE 1300 is Aurora’s most advanced atomic absorption spectrometer. With even better optics and the ability to pipette out of 96-well plates, this spectrometer is the perfect solution for labs carrying out advanced spectroscopy applications.

Flame/Graphite Furnace/Autosampler | Flame/Graphite Furnace/Vapor-Hydride Generator/Autosampler

Atomizers

Flame

  • Fully inert Teflon spray chamber
  • Titanium burner head
  • Built-in high efficiency nebulizer
  • Automatic optimization of the gas flow rate

Graphite Furnace

  • Transversely heated for spatially isothermal heating conditions
  • Industry leading GF tube heating rate
  • Fast Dry technology improves sensitivity, reproducibility and detection limits while decreasing analysis time

Vapor/Hydride Generator

  • Extremely low detection limits for mercury and hydride-forming elements
  • Revolutionary highly efficient gas-liquid separator

Autosampler

Extensive experience in robotics development is behind the creation of the most advanced autosampler on the market, available only from Aurora. These units can sample from virtually an unlimited number of tubes, vials and bottles therefore reducing manual intervention and human error.

Online Dilution

Flame and Flame/GF (with autosampler) TRACE Spectrometers can carry out online dilution, a feature that reduces hands-on time by completing automated sample dilution and calibration curve creation from a standard solution.

AISPEC Software

AISPEC Software is designed to give users complete control of all parameters required to achieve optimal instrument performance. Key features of AISPEC software include:

  • Single and batch run modes
  • Real-time data output
  • Adjustable wavelength scanning range and speed
  • LIMS support
  • FDA Title 21 Part 11 Compliance

Safety

TRACE Atomic Absorption Spectrometers are equipped with extensive safety interlocks to ensure complete user protection. These include:

Electronic interlocks to detect:
  • Combustion head type
  • Gas Pressure
  • Liquid Trap Level
  • Flame Status
  • Atomizer Installation
Power Outage Protection:
  • Automatic gas valve closure
  • Internal air tank to prevent flashback

Elemental Analysis

To learn more about the theory and elements that can be detected using an atomic absorption spectrometer, visit Aurora’s atomic absorption spectroscopy page. For more information, please review the TRACE Atomic Absorption Spectrometer brochure or contact us directly to discuss your specific application. Thank you for considering AURORA to solve your atomic absorption spectroscopy requirements.

Download the TRACE Atomic Absorption Spectrometer Brochure:

Please take a moment to provide us with information that will help us to better assist you.

* Required information

* Salutation/Title:
* Full Name:
* State/Province:
US & Canada only
write 'non-us/can' if not applicable
* Country:
* Company:
* Title:
* Phone: ex. 123456789 no dashes only numbers
* Email:
* How did you hear about Aurora?
If other please provide us with specifics
*Form Validation:

You will be directed to the information after submitting this form. Thank you for visiting Aurora Instruments website.

Please email us if this link will not direct you to the download page, with subject: Atomic Absporption Spectrometer 1200 download link broken

Thank you!